Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 283
Filtrar
1.
Phys Med ; 76: 337-344, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32759035

RESUMEN

Mentoring aims to improve careers and create benefits for the participants' personal and professional lives. Mentoring can be an individual or a shared experience for a group, while the mentor's role remains the same in both models. Mentors should increase confidence, teach, inspire, and set examples, helping the mentees to mould their path, contributing to the pursuit of their personal and professional goals. This study aims to report on the experience of early-career medical physics professionals and postgraduate students participating in a global mentoring program and to assess the impact of this activity on their professional development. The objectives of this mentoring program are to develop leadership roles among young medical physicists and to provide guidance and support. An online questionnaire was administered to the mentee participants. The analysis of their responses is reported in this work and the current status of the programme was examined using a SWOT analysis. In general, the mentoring experience had a positive impact on the mentees. The mentors were found especially helpful in the decision-making situations and in other conflicts that may arise with career development. Additionally, the mentees felt that mentoring contributed to the development of leadership skills required for the job market and assist in personal development. This paper concludes that participation of young medical physicists in a mentoring group program is beneficial to their career and therefore should be encouraged.


Asunto(s)
Tutoría , Mentores , Humanos , Liderazgo , Física , Evaluación de Programas y Proyectos de Salud
2.
Radiat Prot Dosimetry ; 187(4): 451-460, 2019 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-31650160

RESUMEN

This study characterises and evaluates an Al2O3:C-based optically stimulated luminescent dosemeter (OSLD) system, commercially known as the nanoDot™ dosemeter and the InLight® microStar reader, for personal and in vivo dose measurements in diagnostic radiology. The system characteristics, such as dose linearity, reader accuracy, reproducibility, batch homogeneity, energy dependence and signal stability, were explored. The suitability of the nanoDot™ dosemeters was evaluated by measuring the depth dose curve, in vivo dose measurement and image perturbation. The nanoDot™ dosemeters were observed to produce a linear dose with ±2.8% coefficient variation. Significant batch inhomogeneity (8.3%) was observed. A slight energy dependence (±6.1%) was observed between 60 and 140 kVp. The InLight® microStar reader demonstrated good accuracy and a reproducibility of ±2%. The depth dose curve measured using nanoDot™ dosemeters showed slightly lower responses than Monte Carlo simulation results. The total uncertainty for a single dose measurement using this system was 11%, but it could be reduced to 9.2% when energy dependence correction was applied.


Asunto(s)
Método de Montecarlo , Dosimetría con Luminiscencia Ópticamente Estimulada/instrumentación , Dosimetría con Luminiscencia Ópticamente Estimulada/métodos , Dosímetros de Radiación/normas , Radiografía/métodos , Calibración , Simulación por Computador , Humanos , Dosis de Radiación , Reproducibilidad de los Resultados
3.
Radiol Phys Technol ; 12(4): 374-381, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31468370

RESUMEN

This study aimed to evaluate effective dose and size-specific dose estimate (SSDE) of computed tomography angiography (CTA) examination using an anthropomorphic phantom. We included three CTA examination protocols to evaluate the intra- and extra-cranial arteries, pulmonary artery (CTPA), and abdominal vessels. Patient SSDEs were measured retrospectively to estimate patient dose, relative to the bodyweight of the patient and volume CT dose index (CTDIvol). Our findings revealed that the highest dose was absorbed by the left lobe of the thyroid gland during intra-/extra-cranial CTA and CTPA, that is, 14.11 ± 0.24 mGy and 16.20 ± 3.95 mGy, respectively. However, the highest absorbed dose in abdominal/pelvic CTA was the gonads (8.98 ± 0.30 mGy), while other radiosensitive organs in intra- and extra-cranial CTA, CTPA, and abdominal/pelvic CTA did not demonstrate significant differences between organs/structures with p value 0.88, 0.11, and 0.54, respectively. The estimated effective dose in intra-/extra-cranial CTA was lower in patients (0.80 ± 0.60 mSv) than in the phantom (0.83 mSv), but it was the opposite for CTPA, with the effective dose being higher in patients (7.54 ± 3.09 mSv) than in the phantom (6.68 mSv). Similar to the effective dose, only CTPA SSDEs were significantly higher in men than in women (19.74 ± 4.79 mGy versus 7.9 mGy). Effective dose and SSDE are clinically relevant parameters that can help estimate a more accurate patient dose based on a patient's size.


Asunto(s)
Arterias/diagnóstico por imagen , Angiografía por Tomografía Computarizada/instrumentación , Fantasmas de Imagen , Dosis de Radiación , Abdomen/irrigación sanguínea , Adulto , Femenino , Humanos , Pulmón/irrigación sanguínea , Masculino , Pelvis/irrigación sanguínea , Estudios Retrospectivos , Cráneo/irrigación sanguínea
4.
Sci Rep ; 9(1): 1459, 2019 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-30728394

RESUMEN

Synthesized 2D images can be reconstructed from tomosynthesis images in breast imaging. This study aims to investigate the diagnostic efficacy of synthesized 2D images (C-View) in comparison to full field digital mammography (FFDM) when used with digital breast tomosynthesis (DBT) in multi-ethnic Malaysian population. FFDM and C-View images (n = 380) were independently evaluated by three readers through Breast Imaging Reporting and Data System (BI-RADS) categorisation, breast density and lesion characterisation. Statistical analysis was done comparing sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of C-View + DBT with FFDM + DBT as standard of reference. Very good interreader agreement in BI-RADS category and density assessment between C-View + DBT and FFDM + DBT, with high sensitivity, specificity, PPV and NPV of C-View + DBT when compared with FFDM + DBT. There was comparable PPV between C-View + DBT and FFDM + DBT, with histopathology as gold standard. High level of interreader agreement in BI-RADS category and density assessment for FFDM + DBT and C-View + DBT. There was good agreement between FFDM + DBT and C-View + DBT in mass characterization, and almost perfect agreement in calcification and asymmetric density. 52.2% lower radiation dose incurred when using C-View + DBT. Hence, synthesized 2D images are comparable to FFDM with reduction in radiation dose within the limits of Malaysian multi-ethnic population.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Adulto , Anciano , Neoplasias de la Mama/etnología , Detección Precoz del Cáncer , Femenino , Humanos , Malasia/etnología , Mamografía , Persona de Mediana Edad , Sensibilidad y Especificidad
5.
Hong Kong Med J ; 25(1): 58-63, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30713150

RESUMEN

The Centre for Health Protection of the Department of Health has convened the Advisory Group on Antibiotic Stewardship Programme in Primary Care (the Advisory Group) to formulate guidance notes and strategies for optimising judicious use of antibiotics and enhancing the Antibiotic Stewardship Programme in Primary Care. Acute pharyngitis is one of the most common conditions among out-patients in primary care in Hong Kong. Practical recommendations on the diagnosis and antibiotic treatment of acute streptococcal pharyngitis are made by the Advisory Group based on the best available clinical evidence, local prevalence of pathogens and associated antibiotic susceptibility profiles, and common local practice.


Asunto(s)
Antibacterianos/administración & dosificación , Faringitis/tratamiento farmacológico , Infecciones Estreptocócicas/diagnóstico , Streptococcus/aislamiento & purificación , Enfermedad Aguda , Programas de Optimización del Uso de los Antimicrobianos/organización & administración , Hong Kong , Humanos , Faringitis/microbiología , Guías de Práctica Clínica como Asunto , Atención Primaria de Salud/normas , Índice de Severidad de la Enfermedad
6.
Australas Phys Eng Sci Med ; 41(4): 809-810, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30406922

RESUMEN

This policy statement, which is the sixth of a series of documents prepared by the Asia-Oceania Federation of Organizations for Medical Physics (AFOMP) Professional Development Committee, gives guidance on how medical physicists in AFOMP countries should conduct themselves in an ethical manner in their professional practice (Ng et al. in Australas Phys Eng Sci Med 32:175-179, 2009; Round et al. in Australas Phys Eng Sci Med 33:7-10, 2010; Round et al. in Australas Phys Eng Sci Med 34:303-307, 2011; Round et al. in Australas Phys Eng Sci Med 35:393-398, 2012; Round et al. in Australas Phys Eng Sci Med 38:217-221, 2015). It was developed after the ethics policies and codes of conducts of several medical physics societies and other professional organisations were studied. The policy was adopted at the Annual General Meeting of AFOMP held in Jaipur, India, in November 2017.


Asunto(s)
Física Sanitaria , Australasia , Códigos de Ética , Física Sanitaria/ética , Física Sanitaria/legislación & jurisprudencia , Física Sanitaria/normas , Humanos
7.
J Radiol Prot ; 37(4): 883-906, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28836506

RESUMEN

This paper sets out guidelines for managing radiation exposure incidents involving patients in diagnostic and interventional radiology. The work is based on collation of experiences from representatives of international and national organizations for radiologists, medical physicists, radiographers, regulators, and equipment manufacturers, derived from an International Atomic Energy Agency Technical Meeting. More serious overexposures can result in skin doses high enough to produce tissue reactions, in interventional procedures and computed tomography, most notably from perfusion studies. A major factor involved has been deficiencies in training of staff in operation of equipment and optimization techniques. The use of checklists and time outs before procedures commence, and dose alerts when critical levels are reached during procedures, can provide safeguards to reduce the risks of these effects occurring. However, unintended and accidental overexposures resulting in relatively small additional doses can take place in any diagnostic or interventional x-ray procedure and it is important to learn from errors that occur, as these may lead to increased risks of stochastic effects. Such events may involve the wrong examinations, procedural errors, or equipment faults. Guidance is given on prevention, investigation, and dose calculation for radiology exposure incidents within healthcare facilities. Responsibilities should be clearly set out in formal policies, and procedures should be in place to ensure that root causes are identified and deficiencies addressed. When an overexposure of a patient or an unintended exposure of a foetus occurs, the foetal, organ, skin, and/or effective dose may be estimated from exposure data. When doses are very low, generic values for the examination may be sufficient, but a full assessment of doses to all exposed organs and tissues may sometimes be required. The use of general terminology to describe risks from stochastic effects is recommended rather than the calculation of numerical values, as these are misleading when applied to individuals.


Asunto(s)
Diagnóstico por Imagen , Exposición a la Radiación , Traumatismos por Radiación/diagnóstico , Traumatismos por Radiación/prevención & control , Protección Radiológica/métodos , Liberación de Radiactividad Peligrosa/prevención & control , Congresos como Asunto , Humanos , Radiografía Intervencional , Medición de Riesgo
8.
Phys Med ; 32(11): 1466-1474, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27842982

RESUMEN

The purpose of this study is to measure patient skin dose in tangential breast radiotherapy. Treatment planning dose calculation algorithm such as Pencil Beam Convolution (PBC) and in vivo dosimetry techniques such as radiochromic film can be used to accurately monitor radiation doses at tissue depths, but they are inaccurate for skin dose measurement. A MOSFET-based (MOSkin) detector was used to measure skin dose in this study. Tangential breast radiotherapies ("bolus" and "no bolus") were simulated on an anthropomorphic phantom and the skin doses were measured. Skin doses were also measured in 13 patients undergoing each of the techniques. In the patient study, the EBT2 measurements and PBC calculation tended to over-estimate the skin dose compared with the MOSkin detector (p<0.05) in the "no bolus radiotherapy". No significant differences were observed in the "bolus radiotherapy" (p>0.05). The results from patients were similar to that of the phantom study. This shows that the EBT2 measurement and PBC calculation, while able to predict accurate doses at tissue depths, are inaccurate in predicting doses at build-up regions. The clinical application of the MOSkin detectors showed that the average total skin doses received by patients were 1662±129cGy (medial) and 1893±199cGy (lateral) during "no bolus radiotherapy". The average total skin doses were 4030±72cGy (medial) and 4004±91cGy (lateral) for "bolus radiotherapy". In some cases, patient skin doses were shown to exceed the dose toxicity level for skin erythema. Hence, a suitable device for in vivo dosimetry is necessary to accurately determine skin dose.


Asunto(s)
Neoplasias de la Mama/radioterapia , Radiometría/instrumentación , Piel/efectos de la radiación , Algoritmos , Humanos , Órganos en Riesgo/efectos de la radiación , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador , Rotación
9.
Eur Radiol ; 26(1): 79-86, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26002131

RESUMEN

OBJECTIVES: To develop a real-time dose-monitoring system to measure the patient's eye lens dose during neuro-interventional procedures. METHODS: Radiation dose received at left outer canthus (LOC) and left eyelid (LE) were measured using Metal-Oxide-Semiconductor Field-Effect Transistor dosimeters on 35 patients who underwent diagnostic or cerebral embolization procedures. RESULTS: The radiation dose received at the LOC region was significantly higher than the dose received by the LE. The maximum eye lens dose of 1492 mGy was measured at LOC region for an AVM case, followed by 907 mGy for an aneurysm case and 665 mGy for a diagnostic angiography procedure. Strong correlations (shown as R(2)) were observed between kerma-area-product and measured eye doses (LOC: 0.78, LE: 0.68). Lateral and frontal air-kerma showed strong correlations with measured dose at LOC (AKL: 0.93, AKF: 0.78) and a weak correlation with measured dose at LE. A moderate correlation was observed between fluoroscopic time and dose measured at LE and LOC regions. CONCLUSIONS: The MOSkin dose-monitoring system represents a new tool enabling real-time monitoring of eye lens dose during neuro-interventional procedures. This system can provide interventionalists with information needed to adjust the clinical procedure to control the patient's dose. KEY POINTS: Real-time patient dose monitoring helps interventionalists to monitor doses. Strong correlation was observed between kerma-area-product and measured eye doses. Radiation dose at left outer canthus was higher than at left eyelid.


Asunto(s)
Angiografía Cerebral/métodos , Cristalino/efectos de la radiación , Embolización Terapéutica/métodos , Diseño de Equipo , Femenino , Fluoroscopía/métodos , Humanos , Aneurisma Intracraneal/terapia , Masculino , Persona de Mediana Edad , Dosis de Radiación , Radiografía Intervencional/métodos
10.
Lupus ; 25(4): 399-406, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26537422

RESUMEN

We have previously reported the one-year outcomes of 16 children with severe proliferative lupus nephritis (LN) who were treated using a multi-targeted induction protocol based on intravenous (IV) pulse methylprednisolone (MP), mycophenolate mofetil (MMF) and cyclosporine (CSA). This study examined the long-term renal outcomes of these 16 children, followed up for a median duration of 9.2 years (range 5.8-14.2 years). Primary treatment outcome was complete renal remission. Secondary outcomes included patient and renal survival as well as relapse-free and event-free survival. All patients achieved complete renal remission within 24 months (median 8.7 months, range 4.0-24.0 months). Comparing clinical and laboratory parameters at induction and last follow-up, respectively, Systemic Lupus Erythematosus Disease Activity Index (SLEDAI) score (25.4 ± 8.7 vs. 0.4 ± 0.8), serum complement C3 (47 ± 21 vs. 107 ± 27 mg/dL), estimated glomerular filtration rate (eGFR) (72 ± 57 vs. 109.7 ± 43 ml/min/1.73 m2) and urine protein (6.97 ± 7.09 vs. 0.2 ± 0.02 g/day/1.73 m2) improved significantly (p < 0.05). Kaplan-Meier survival analysis showed a cumulative ten-year renal relapse-free survival of 73.3% when considering relapses with severe proteinuria >1 g/day/1.73 m2. Cumulative probability that hospitalization would not be required was 93.8% at one year, and 71.4% at ten years. Our multi-targeted protocol for induction and maintenance therapy in Asian children with severe proliferative LN resulted in good long-term patient survival and renal preservation, with a good safety profile.


Asunto(s)
Ciclosporina/administración & dosificación , Inmunosupresores/administración & dosificación , Nefritis Lúpica/tratamiento farmacológico , Metilprednisolona/administración & dosificación , Ácido Micofenólico/administración & dosificación , Administración Intravenosa , Adolescente , Factores de Edad , Niño , Preescolar , Supervivencia sin Enfermedad , Quimioterapia Combinada , Femenino , Estudios de Seguimiento , Hospitalización , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Nefritis Lúpica/diagnóstico , Nefritis Lúpica/inmunología , Masculino , Quimioterapia por Pulso , Recurrencia , Inducción de Remisión , Factores de Riesgo , Índice de Severidad de la Enfermedad , Singapur , Factores de Tiempo , Resultado del Tratamiento
12.
Australas Phys Eng Sci Med ; 38(3): 493-501, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26346030

RESUMEN

It was the aim of this work to assess and track the workload, working conditions and professional recognition of radiation oncology medical physicists (ROMPs) in the Asia Pacific region over time. In this third survey since 2008, a structured questionnaire was mailed in 2014 to 22 senior medical physicists representing 23 countries. As in previous surveys the questionnaire covered seven themes: 1 education, training and professional certification, 2 staffing, 3 typical tasks, 4 professional organisations, 5 resources, 6 research and teaching, and 7 job satisfaction. The response rate of 100% is a result of performing a survey through a network, which allows easy follow-up. The replies cover 4841 ROMPs in 23 countries. Compared to 2008, the number of medical physicists in many countries has doubled. However, the number of experienced ROMPs compared to the overall workforce is still small, especially in low and middle income countries. The increase in staff is matched by a similar increase in the number of treatment units over the years. Furthermore, the number of countries using complex techniques (IMRT, IGRT) or installing high end equipment (tomotherapy, robotic linear accelerators) is increasing. Overall, ROMPs still feel generally overworked and the professional recognition, while varying widely, appears to be improving only slightly. Radiation oncology medical physics practice has not changed significantly over the last 6 years in the Asia Pacific Region even if the number of physicists and the number and complexity of treatment techniques and technologies have increased dramatically.


Asunto(s)
Personal de Salud/estadística & datos numéricos , Medicina Nuclear/estadística & datos numéricos , Oncología por Radiación/estadística & datos numéricos , Asia , Humanos , Encuestas y Cuestionarios , Carga de Trabajo
13.
Am J Transplant ; 15(12): 3229-38, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26147534

RESUMEN

Individuals with TRPC6 mutations have variable phenotypes, ranging from healthy carrier to focal segmental glomerulosclerosis (FSGS) leading to renal failure. Here, we describe a family where six members had a novel TRPC6 p.R68W (c.202C>T) mutation, two of whom had renal failure from FSGS, and one had proteinuria. One healthy carrier donated a kidney to her sister. Both donor and recipient had no proteinuria at 20 years posttransplant. Two synonymous NPHS1 polymorphisms, rs2285450 (c.294C>T) and rs437168 (c.2289C>T) segregated with renal failure in this family. These variants had higher allele frequencies in 97 unrelated patients with nephrotic syndrome or FSGS compared to 224 controls. Using patch-clamp experiments in HEK293 and podocytes, we showed that the p.R68W mutation increased TRPC6 current amplitudes, which may be explained by enhanced TRPC6 surface expression. Additionally, while wild-type nephrin suppressed TRPC6 currents, this ability was lost in the presence of NPHS1 c.294C>T polymorphism. When cells were transfected according to combined TRPC6 and NPHS1 genotypes in the family, those representing the donor had lower TRPC6 currents than cells representing the recipient, suggesting that interactions between TRPC6 and NPHS1 variants could possibly account for the variable penetrance of TRPC6 mutations and the absence of recurrence in the graft.


Asunto(s)
Glomeruloesclerosis Focal y Segmentaria/etiología , Trasplante de Riñón/efectos adversos , Proteínas de la Membrana/genética , Mutación/genética , Polimorfismo de Nucleótido Simple/genética , Canales Catiónicos TRPC/genética , Adolescente , Adulto , Anciano , Animales , Western Blotting , Estudios de Casos y Controles , Niño , Preescolar , Femenino , Estudios de Seguimiento , Frecuencia de los Genes , Genotipo , Tasa de Filtración Glomerular , Glomeruloesclerosis Focal y Segmentaria/patología , Rechazo de Injerto/etiología , Rechazo de Injerto/patología , Supervivencia de Injerto , Células HEK293 , Humanos , Lactante , Pruebas de Función Renal , Masculino , Ratones , Ratones Noqueados , Persona de Mediana Edad , Linaje , Fenotipo , Podocitos , Complicaciones Posoperatorias , Pronóstico , Recurrencia , Factores de Riesgo , Canal Catiónico TRPC6 , Adulto Joven
14.
Australas Phys Eng Sci Med ; 38(2): 217-21, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26076746

RESUMEN

This policy statement, which is the fifth of a series of documents being prepared by the Asia-Oceania Federation of Organizations for Medical Physics Professional Development Committee, gives guidance on how clinical medical physicists' careers should progress from their initial training to career end. It is not intended to be prescriptive as in some AFOMP countries career structures are already essentially defined by employment awards and because such matters will vary considerably from country to country depending on local culture, employment practices and legislation. It is intended to be advisory and set out options for member countries and employers of clinical medical physicists to develop suitable career structures.


Asunto(s)
Movilidad Laboral , Educación Profesional , Física Sanitaria/educación , Sociedades Científicas , Curriculum , Empleo , Humanos
15.
Med Phys ; 42(5): 2550-8, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25979047

RESUMEN

PURPOSE: The MOSkin is a MOSFET detector designed especially for skin dose measurements. This detector has been characterized for various factors affecting its response for megavoltage photon beams and has been used for patient dose measurements during radiotherapy procedures. However, the characteristics of this detector in kilovoltage photon beams and low dose ranges have not been studied. The purpose of this study was to characterize the MOSkin detector to determine its suitability for in vivo entrance skin dose measurements during interventional radiology procedures. METHODS: The calibration and reproducibility of the MOSkin detector and its dependency on different radiation beam qualities were carried out using RQR standard radiation qualities in free-in-air geometry. Studies of the other characterization parameters, such as the dose linearity and dependency on exposure angle, field size, frame rate, depth-dose, and source-to-surface distance (SSD), were carried out using a solid water phantom under a clinical x-ray unit. RESULTS: The MOSkin detector showed good reproducibility (94%) and dose linearity (99%) for the dose range of 2 to 213 cGy. The sensitivity did not significantly change with the variation of SSD (± 1%), field size (± 1%), frame rate (± 3%), or beam energy (± 5%). The detector angular dependence was within ± 5% over 360° and the dose recorded by the MOSkin detector in different depths of a solid water phantom was in good agreement with the Markus parallel plate ionization chamber to within ± 3%. CONCLUSIONS: The MOSkin detector proved to be reliable when exposed to different field sizes, SSDs, depths in solid water, dose rates, frame rates, and radiation incident angles within a clinical x-ray beam. The MOSkin detector with water equivalent depth equal to 0.07 mm is a suitable detector for in vivo skin dosimetry during interventional radiology procedures.


Asunto(s)
Radiología Intervencionista/instrumentación , Radiología Intervencionista/métodos , Radiometría/instrumentación , Radiometría/métodos , Piel/efectos de la radiación , Calibración , Relación Dosis-Respuesta en la Radiación , Fluoroscopía/instrumentación , Fluoroscopía/métodos , Humanos , Modelos Lineales , Fantasmas de Imagen , Dosificación Radioterapéutica , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Agua
16.
Australas Phys Eng Sci Med ; 38(3): 381-98, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25894289

RESUMEN

The history of medical physics in Asia-Oceania goes back to the late nineteenth century when X-ray imaging was introduced, although medical physicists were not appointed until much later. Medical physics developed very quickly in some countries, but in others the socio-economic situation as such prevented it being established for many years. In others, the political situation and war has impeded its development. In many countries their medical physics history has not been well recorded and there is a danger that it will be lost to future generations. In this paper, brief histories of the development of medical physics in most countries in Asia-Oceania are presented by a large number of authors to serve as a record. The histories are necessarily brief; otherwise the paper would quickly turn into a book of hundreds of pages. The emphasis in each history as recorded here varies as the focus and culture of the countries as well as the length of their histories varies considerably.


Asunto(s)
Biofisica/historia , Asia , Historia de la Medicina , Historia del Siglo XIX , Historia del Siglo XX , Historia del Siglo XXI , Humanos , Oceanía
17.
Arch Dis Child Educ Pract Ed ; 100(3): 114-21, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25112285

RESUMEN

Tuberous sclerosis complex is a complex childhood disorder characterised by the formation of hamartomas in multiple organs. Annual review of this disease is recommended to monitor the development of complications. We aim to provide a concise, evidence-based framework to assist clinicians during this annual review. We focus on the following areas: (A) what questions need to be asked during annual review, (B) which areas need emphasis on examination, (C) when is an investigation required and (D) referral to tertiary specialists and other members of the multidisciplinary team. It should also be noted that there are ongoing debates regarding screening intervals in certain areas. These include the frequency, modality of screening and degree of intervention for astrocytomas and renal angiomyolipomas. This review seeks to summarise the product of the ongoing debates, and provide evidence-based suggestions in light of the uncertainty.


Asunto(s)
Esclerosis Tuberosa/complicaciones , Esclerosis Tuberosa/diagnóstico , Niño , Humanos , Esclerosis Tuberosa/genética
18.
Phys Med ; 30(8): 980-4, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25086486

RESUMEN

Cobalt-60 (Co-60) is a relatively new source for the application of high-dose rate (HDR) brachytherapy. Radiation dose to the rectum is often a limiting factor in achieving the full prescribed dose to the target during brachytherapy of cervical cancer. The aim of this study was to measure radiation doses to the rectum in-vivo during HDR Co-60 brachytherapy. A total of eleven HDR brachytherapy treatments of cervical cancer were recruited in this study. A series of diodes incorporated in a rectal probe was inserted into the patient's rectum during each brachytherapy procedure. Real-time measured rectal doses were compared to calculated doses by the treatment planning system (TPS). The differences between calculated and measured dose ranged from 8.5% to 41.2%. This corresponds to absolute dose differences ranging from 0.3 Gy to 1.5 Gy. A linear relationship was observed between calculated and measured doses with linear regression R(2) value of 0.88, indicating close association between the measured and calculated doses. In general, absorbed doses for the rectum as calculated by TPS were observed to be higher than the doses measured using the diode probe. In-vivo dosimetry is an important quality assurance method for HDR brachytherapy of cervical cancer. It provides information that can contribute to the reduction of errors and discrepancies in dose delivery. Our study has shown that in-vivo dosimetry is feasible and can be performed to estimate the dose to the rectum during HDR brachytherapy using Co-60.


Asunto(s)
Braquiterapia/métodos , Radioisótopos de Cobalto/uso terapéutico , Recto/efectos de la radiación , Neoplasias del Cuello Uterino/radioterapia , Braquiterapia/efectos adversos , Femenino , Humanos , Dosis de Radiación , Radiometría/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Reproducibilidad de los Resultados , Programas Informáticos
19.
Indian J Otolaryngol Head Neck Surg ; 66(Suppl 1): 169-72, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24533378

RESUMEN

The objective of this study is to assess high frequency hearing (above 8 kHz) loss among prolonged mobile phone users is a tertiary Referral Center. Prospective single blinded study. This is the first study that used high-frequency audiometry. The wide usage of mobile phone is so profound that we were unable to find enough non-users as a control group. Therefore we compared the non-dominant ear to the dominant ear using audiometric measurements. The study was a blinded study wherein the audiologist did not know which was the dominant ear. A total of 100 subjects were studied. Of the subjects studied 53% were males and 47% females. Mean age was 27. The left ear was dominant in 63%, 22% were dominant in the right ear and 15% did not have a preference. This study showed that there is significant loss in the dominant ear compared to the non-dominant ear (P < 0.05). Chronic usage mobile phone revealed high frequency hearing loss in the dominant ear (mobile phone used) compared to the non dominant ear.

20.
Am J Hosp Palliat Care ; 31(3): 281-6, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-23650644

RESUMEN

UNLABELLED: REASON FOR THE STUDY: Studies on methylphenidate for cancer-related fatigue showed conflicting results. This prospective study aims to determine whether methylphenidate is useful for relieving fatigue in Chinese patients with cancer. Chinese Version of Brief Fatigue Inventory (BFI-C) was administered on days 1, 8, and 29. Methylphenidate dose on day 1 was 5 mg daily then adjusted after day 8 according to response and side effects tolerance. MAIN FINDINGS: Only 48% of the 25 recruited patients were on methylphenidate by day 29. Overall, no significant improvement in fatigue level was observed after methylphenidate, though benefits were shown in subgroups with age ≤ 65 and higher baseline BFI-C values. PRINCIPAL CONCLUSIONS: Methylphenidate may be useful for management of cancer-related fatigue in selected Chinese patients.


Asunto(s)
Estimulantes del Sistema Nervioso Central/uso terapéutico , Fatiga/tratamiento farmacológico , Metilfenidato/uso terapéutico , Neoplasias/complicaciones , Factores de Edad , Anciano , Anciano de 80 o más Años , Fatiga/diagnóstico , Fatiga/etiología , Femenino , Hong Kong , Humanos , Masculino , Persona de Mediana Edad , Cuidados Paliativos/métodos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...